Air cooled condenser

A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state.

An air cooled condenser is a condenser in which heat is transferred to an air-stream.

IfcElementType IfcCondenser =IfcExportAs
IfcPredefinedType AIRCOOLED =IfcExportType
Suggested Filename Condenser_Air
Suggested LOD (Design Model) 200
Suggested Primary Discipline Mechanical
Specific classifications
(Select the classification you'd like to be included in the Excel export)
AusHFG
ICMS
NATSPEC
OmniClass 21 Elements
OmniClass 22 Work Results
OmniClass 23 Products
Uniclass EF Elements Functions
Uniclass Pr Products
Uniclass Ss Systems
UniFormat
PropertySourceDescriptionValueUnit
Admin - Classification properties
Reference
Pset_DistributionFlowElementCommon (IFC2X3)

Reference ID for this specific instance (e.g. 'WWS/VS1/400/001', which indicates the occurrence belongs to system WWS, subsystems VSI/400, and has the component number 001).

-
Reference
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Reference ID for this specified type in this project (e.g. type 'A-1'), provided, if there is no classification reference to a recognized classification system used.

-
SpecificationCode
OBOS Optional

Specification clause or section code/reference.

-
SpecificationSystem
OBOS Optional

Name of the specification system being used.

-
SpecificationTitle
OBOS Optional

Specification clause or section title.

-
SpecificationVersion
OBOS Optional

Published version of the classification system.

-
FlangeTable
Pset_PipeConnectionFlanged (IFC2X3)

Designation of the standard table to which the flange conforms.

-
FlangeStandard
Pset_PipeConnectionFlanged (IFC2X3)

Designation of the standard describing the flange table.

-
Admin - Cost properties
AdditionalTax
NATSPEC BIM
-
AssemblyCost
NATSPEC BIM
-
ConceptualCost
NATSPEC BIM
-
CostOverRun
NATSPEC BIM
-
FutureCostAssumptions
NATSPEC BIM
-
InstallationCost
NATSPEC BIM
-
InstalledCost
NATSPEC BIM
-
PurchaseInformation
NATSPEC BIM
-
RecordedActualCost
NATSPEC BIM
-
ShippingCost
NATSPEC BIM
-
TotalOwnershipCost
NATSPEC BIM
-
Admin - Identification properties
GISTag
NATSPEC BIM
-
GPSTag
NATSPEC BIM
-
ArticleNumber
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

Article number or reference that may be applied to a product according to a standard scheme for article number definition (e.g. UN, EAN).

-
ModelReference
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
NATSPEC Spec
OBOS Mandatory

The name of the manufactured item as used by the manufacturer.

-
ModelLabel
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
NATSPEC Spec
OBOS Mandatory

The model number and/or unit designator assigned by the manufacturer of the manufactured item.

-
BarCode
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The identity of the bar code given to an occurrence of the product.

-
SerialNumber
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The serial number assigned to an occurrence of a product.

-
BatchReference
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The identity of the batch reference from which an occurrence of a product is taken.

-
GlobalTradeItemNumber
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org).

-
Admin - Maintenance properties
AcquisitionDate
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The date that the manufactured item was purchased.

-
ServiceLifeDuration
Pset_ServiceLife (IFC4)
OBOS Optional

The length or duration of a service life. The lower bound indicates pessimistic service life, the upper bound indicates optimistic service life, and the setpoint indicates the typical service life.

-
MeanTimeBetweenFailure
Pset_ServiceLife (IFC4)
OBOS Optional

The average time duration between instances of failure of a product.

-
WarrantyIdentifier
Pset_Warranty (IFC4)
OBOS Optional

The identifier assigned to a warranty.

-
WarrantyStartDate
Pset_Warranty (IFC4)
OBOS Optional

The date on which the warranty commences.

-
WarrantyEndDate
Pset_Warranty (IFC4)
OBOS Optional

The date on which the warranty expires.

-
IsExtendedWarranty
Pset_Warranty (IFC4)
OBOS Optional

Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE).

-
WarrantyPeriod
Pset_Warranty (IFC4)
OBOS Optional

The time duration during which a manufacturer or supplier guarantees or warrants the performance of an artefact.

-
WarrantyContent
Pset_Warranty (IFC4)
OBOS Optional

The content of the warranty.

-
Exclusions
Pset_Warranty (IFC4)
OBOS Optional

Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void.

-
AssessmentDate
Pset_Condition (IFC4)
OBOS Optional

Date on which the overall condition is assessed.

-
AssessmentCondition
Pset_Condition (IFC4)
OBOS Optional

The overall condition of a product based on an assessment of the contributions to the overall condition made by the various criteria considered. The meanings given to the values of assessed condition should be agreed and documented by local agreements. For instance, is overall condition measured on a scale of 1 - 10 or by assigning names such as Good, OK, Poor.

-
AssessmentDescription
Pset_Condition (IFC4)
OBOS Optional

Qualitative description of the condition.

-
Admin - Metadata properties
CreatedBy
OBOS Mandatory

The name of the person, organisation or library provider that created the object.

-
CreatedByURL
OBOS Mandatory

URL hyperlink to the object creator’s website.

-
ModifiedIssue
OBOS Mandatory

To record the last date of issue (version or revision) of the object within an object library. Add the date in the following format <yyyymmdd.no> where the ‘no’ suffix is equal to the number of times the object has been issued on that date. For example 20180316.01.

-
Admin - Production properties
Availability
NATSPEC BIM
-
OrderNumber
NATSPEC BIM
-
ManufacturerURL
OBOS Mandatory

URL hyperlink to the manufacturer’s website.

-
ProductURL
OBOS Mandatory

URL hyperlink to further product information, such as technical documentation or installation guides.

-
Status
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).

-
Manufacturer
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
NATSPEC Spec
OBOS Mandatory

The organization that manufactured and/or assembled the item.

-
AssemblyPlace
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

Enumeration defining where the assembly is intended to take place, either in a factory or on the building site.

-
PointOfContact
Pset_Warranty (IFC4)
OBOS Optional

The organization that should be contacted for action under the terms of the warranty. Note that the role of the organization (manufacturer, supplier, installer etc.) is determined by the IfcActorRole attribute of IfcOrganization.

-
Compositional - Construction properties
NumberOfPoles
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

The number of live lines that is intended to be handled by the device.

-
HasProtectiveEarth
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

Indicates whether the electrical device has a protective earth connection (=TRUE) or not (= FALSE).

-
Accessories
NATSPEC BIM

Details of available accessories.

-
HasSoundAttentuation
Pset_EnergyConversionDeviceCoil (IFC2X3)

TRUE if the coil has sound attenuation, FALSE if it does not.

-
NumberOfBoltholes
Pset_PipeConnectionFlanged (IFC2X3)

Number of boltholes in the flange.

-
ConnectionType
Pset_PipeConnection (IFC2X3)

The connection type between pipe segments or fittings and other segments or fittings. If the list contains only one value, then this connection type value applies to all ports. For more than one value in the list, the connection type value applies to the port that corresponds to the list index.The following suggested items should be utilized whenever possible for correlation with port enumerations: BRAZED: Brazed connection type. COMPRESSION: Compression connection type. FLANGED: Flanged connection type including bolts and gasket. GLANDJOINT: Gland-joint connection type. FLEXIBLEBOLTEDGLANDJOINT: Flexible bolted gland-joint connection type. FLEXIBLEBOLTEDGLANDJOINTWITHANODEENDCAP: Flexible bolted gland-joint with anode end-cap connection type. GROOVED: Grooved connection type. SOLDERED: Soldered connection type. SOLDERED_FEMALE: Female-soldered connection type. SOLDERED_MALE: Male-soldered connection type. SWEDGE: Swedge connection type. THREADED: Threaded connection type. THREADED_FEMALE: Female-threaded connection type. THREADED_MALE: Male-threaded connection type. WELDED: Welded connection type. WELDED_BUTT: Butt-welded connection type. WELDED_BRANCH: Branch-welded connection type. WELDED_FLANGE: Flange-welded connection type. NONE: There is no connection. NOTDEFINED: Undefined connection type.

-
Compositional - Mass properties
GrossWeight
Qto_CondenserBaseQuantities (IFC4)

Weight of the element.

-
Compositional - Material properties
RecycledContent
NATSPEC BIM
-
RefrigerantClass
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Refrigerant class used by the condenser. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons.

-
RefrigerantType
Pset_CondenserTypeCommon (IFC2X3)

Refrigerant material.

-
Material
Pset_PipeConnectionFlanged (IFC2X3)

Material from which the pipe flange is constructed.

-
Compositional - Quality properties
IP_Code
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

IP Code, the International Protection Marking, IEC 60529), classifies and rates the degree of protection provided against intrusion.

-
IK_Code
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

IK Code according to IEC 62262 (2002) is a numeric classification for the degree of protection provided by enclosures for electrical equipment against external mechanical impacts. > NOTE  In earlier labeling, the third numeral (1..) had been occasionally added to the closely related IP Code on ingress protection, to indicate the level of impact protection.

-
Defects
NATSPEC BIM

To record any defects found.

-
Geometric - Area properties
ExternalSurfaceArea
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

External surface area (both primary and secondary area).

InternalSurfaceArea
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Internal surface area.

NominalHeatTransferArea
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Nominal heat transfer surface area associated with nominal overall heat transfer coefficient.

Geometric - Dimensional properties
BoreSize
Pset_PipeConnectionFlanged (IFC2X3)

The nominal bore of the pipe flange.

m
FlangeDiameter
Pset_PipeConnectionFlanged (IFC2X3)

Overall diameter of the flange.

m
FlangeThickness
Pset_PipeConnectionFlanged (IFC2X3)

Thickness of the material from which the pipe bend is constructed.

m
BoltSize
Pset_PipeConnectionFlanged (IFC2X3)

Size of the bolts securing the flange.

m
BoltholePitch
Pset_PipeConnectionFlanged (IFC2X3)

Diameter of the circle along which the boltholes are placed.

m
Geometric - Volume properties
InternalRefrigerantVolume
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Internal volume of condenser (refrigerant side).

InternalWaterVolume
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Internal volume of condenser (water side).

Performance - Acoustic properties
SoundCurve
Pset_SoundGeneration (IFC4)
OBOS Optional

Table of sound frequencies and sound power measured in decibels at a reference power of 1 picowatt(10^(-12) watt) for the referenced octave band frequency.

Hz
Performance - Electrical properties
RatedCurrent
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

The current that a device is designed to handle.

A
RatedVoltage
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

The voltage that a device is designed to handle.

V
NominalFrequencyRange
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

The upper and lower limits of frequency for which the operation of the device is certified.

Hz
PowerFactor
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

The ratio between the rated electrical power and the product of the rated current and rated voltage.

-
ConductorFunction
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

Function of a line conductor to which a device is intended to be connected where L1, L2 and L3 represent the phase lines according to IEC 60446 notation (sometimes phase lines may be referenced by color [Red, Blue, Yellow] or by number [1, 2, 3] etc). Protective Earth is sometimes also known as CPC or common protective conductor. Note that for an electrical device, a set of line conductor functions may be applied.

-
InsulationStandardClass
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

Insulation standard classes provides basic protection information against electric shock. Defines levels of insulation required in terms of constructional requirements (creepage and clearance distances) and electrical requirements (compliance with electric strength tests). Basic insulation is considered to be shorted under single fault conditions. The actual values required depend on the working voltage to which the insulation is subjected, as well as other factors. Also indicates whether the electrical device has a protective earth connection.

-
NominalCurrent
Pset_ElectricalDeviceCommon (IFC2X3)

The maximum allowed current that a device is certified to handle.

A
UsageCurrent
Pset_ElectricalDeviceCommon (IFC2X3)

The current that a device is actually handling or is calculated to be handling at a point in time.

A
NominalVoltage
Pset_ElectricalDeviceCommon (IFC2X3)

The range of allowed voltage that a device is certified to handle. The upper bound of this value is the maximum.

V
ElectricalDeviceNominalPower
Pset_ElectricalDeviceCommon (IFC2X3)

The output power rating that is certified for a device.

W
PhaseAngle
Pset_ElectricalDeviceCommon (IFC2X3)

The angular difference between two waveforms of the same frequency.

rad
PhaseReference
Pset_ElectricalDeviceCommon (IFC2X3)

The phase identification used for the device electrical input. This should be the same phase identifier that is used for the conductor segment providing the electrical service to the device. In general, it is recommended that IEC recommendations for phase identification are used (L1, L2 etc.). However, other phase identifiers may be used such as by color (Red, Blue, Yellow) or by number (1, 2, 3) etc.

-
Performance - Environmental properties
CarbonFootprint
NATSPEC BIM
-
ItemIsNew
NATSPEC BIM
-
ItemIsPartiallyRecycled
NATSPEC BIM
-
ItemIsRecycled
NATSPEC BIM
-
PostConsumerRecycledContent
NATSPEC BIM
-
PostIndustrialRecycledContent
NATSPEC BIM
-
PreConsumerRecycledContent
NATSPEC BIM
-
FunctionalUnitReference
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Reference to a database or a classification.

-
Unit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

The unit of the quantity the environmental indicators values are related with.

-
LifeCyclePhase
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

The whole life cycle or only a given phase from which environmental data are valid.

-
ExpectedServiceLife
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Expected service life in years.

s
TotalPrimaryEnergyConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of energy used as defined in ISO21930:2007.

J
WaterConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of water used.

HazardousWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of hazardous waste generated.

kg
NonHazardousWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of non hazardous waste generated.

kg
ClimateChangePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of greenhouse gases emitted calculated in equivalent CO2.

kg
AtmosphericAcidificationPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2.

kg
RenewableEnergyConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of renewable energy used as defined in ISO21930:2007.

J
NonRenewableEnergyConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of non-renewable energy used as defined in ISO21930:2007.

J
ResourceDepletionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of resources used calculated in equivalent antimony.

kg
InertWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of inert waste generated.

kg
RadioactiveWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of radioactive waste generated.

kg
StratosphericOzoneLayerDestructionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11.

kg
PhotochemicalOzoneFormationPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of gases creating the photochemical ozone calculated in equivalent ethylene.

kg
EutrophicationPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of eutrophicating compounds calculated in equivalent PO4.

kg
TotalPrimaryEnergyConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of energy used as defined in ISO21930:2007.

J
WaterConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of water used.

HazardousWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of hazardous waste generated.

kg
NonHazardousWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of non hazardous waste generated.

kg
ClimateChange
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of greenhouse gases emitted calculated in equivalent CO2.

kg
AtmosphericAcidification
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2.

kg
RenewableEnergyConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of renewable energy used as defined in ISO21930:2007.

J
NonRenewableEnergyConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of non-renewable energy used as defined in ISO21930:2007.

J
ResourceDepletion
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of resources used calculated in equivalent antimony.

kg
InertWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of inert waste generated.

kg
RadioactiveWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of radioactive waste generated.

kg
StratosphericOzoneLayerDestruction
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11.

kg
PhotochemicalOzoneFormation
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of gases creating the photochemical ozone calculated in equivalent ethylene.

kg
Eutrophication
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of eutrophicating compounds calculated in equivalent PO4.

kg
Performance - Fire properties
FireResistanceRating
Pset_FireRatingProperties (IFC2X3)

Fire rating identifying the entity's fire resistive value (e.g., 1-hour, 2-hour, etc.) so that its resistance to fire can be compared to that of the surrounding structure.

-
IsCombustible
Pset_FireRatingProperties (IFC2X3)

Combustibility (YES it is combustible or NO it is not combustible).

-
SurfaceSpreadOfFlame
Pset_FireRatingProperties (IFC2X3)

Surface spread of flame characteristics.

-
Performance - Thermal properties
NominalHeatTransferCoefficient
Pset_CondenserTypeCommon (IFC2X3)
Pset_CondenserTypeCommon (IFC4)
OBOS Mandatory

Nominal overall heat transfer coefficient associated with nominal heat transfer area.

W/(m².K)
Performance - Usage properties
HeatRejectionRate
Pset_CondenserPHistory (IFC4)
OBOS Optional

Sum of the refrigeration effect and the heat equivalent of the power input to the compressor.

-
ExteriorHeatTransferCoefficient
Pset_CondenserPHistory (IFC4)
OBOS Optional

Exterior heat transfer coefficient associated with exterior surface area.

-
InteriorHeatTransferCoefficient
Pset_CondenserPHistory (IFC4)
OBOS Optional

Interior heat transfer coefficient associated with interior surface area.

-
RefrigerantFoulingResistance
Pset_CondenserPHistory (IFC4)
OBOS Optional

Fouling resistance on the refrigerant side.

-
CondensingTemperature
Pset_CondenserPHistory (IFC4)
OBOS Optional

Refrigerant condensing temperature.

-
LogarithmicMeanTemperatureDifference
Pset_CondenserPHistory (IFC4)
OBOS Optional

Logarithmic mean temperature difference between refrigerant and water or air.

-
UAcurves
Pset_CondenserPHistory (IFC4)
OBOS Optional

UV = f (VExterior, VInterior), UV as a function of interior and exterior fluid flow velocity at the entrance.

-
CompressorCondenserHeatGain
Pset_CondenserPHistory (IFC4)
OBOS Optional

Heat gain between condenser inlet to compressor outlet.

-
CompressorCondenserPressureDrop
Pset_CondenserPHistory (IFC4)
OBOS Optional

Pressure drop between condenser inlet and compressor outlet.

-
CondenserMeanVoidFraction
Pset_CondenserPHistory (IFC4)
OBOS Optional

Mean void fraction in condenser.

-
WaterFoulingResistance
Pset_CondenserPHistory (IFC4)
OBOS Optional

Fouling resistance on water/air side.

-
Time - Object time properties
DeliverBy
NATSPEC BIM
-
FabricationTime
NATSPEC BIM
-
InstallationSequence
NATSPEC BIM
-
InstallationTime
NATSPEC BIM
-
LeadTime
NATSPEC BIM
-
ProductionYear
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

The year of production of the manufactured item.

-
Time - Project time properties
LeadInTime
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Lead in time before start of process.

-
Duration
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Duration of process.

-
LeadOutTime
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Lead out time after end of process.

-
Application version 2.0.3.1   Data version 2.0.3