Sump pump
A pump is a device which imparts a mechanical action on fluids or slurries to move them through a channel or pipeline.
A sump pump is designed to sit above a collection tank with a suction inlet extending into the tank.
IfcElementType | IfcPump | =IfcExportAs |
---|---|---|
IfcPredefinedType | SUMPPUMP | =IfcExportType |
Suggested Filename | Pump_Sump | |
Suggested LOD (Design Model) | 200 | |
Suggested Primary Discipline | Mechanical, Hydraulic |
Property | Source | Description | Value | Unit |
---|---|---|---|---|
Admin - Classification properties | ||||
Reference | Pset_DistributionFlowElementCommon (IFC2X3) | Reference ID for this specific instance (e.g. 'WWS/VS1/400/001', which indicates the occurrence belongs to system WWS, subsystems VSI/400, and has the component number 001). | - | |
Reference | Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Reference ID for this specified type in this project (e.g. type 'A-1'). | - | |
SpecificationCode | OBOS Optional | Specification clause or section code/reference. | - | |
SpecificationSystem | OBOS Optional | Name of the specification system being used. | - | |
SpecificationTitle | OBOS Optional | Specification clause or section title. | - | |
SpecificationVersion | OBOS Optional | Published version of the classification system. | - | |
FlangeTable | Pset_PipeConnectionFlanged (IFC2X3) | Designation of the standard table to which the flange conforms. | - | |
FlangeStandard | Pset_PipeConnectionFlanged (IFC2X3) | Designation of the standard describing the flange table. | - | |
Admin - Cost properties | ||||
AdditionalTax | NATSPEC BIM | - | ||
AssemblyCost | NATSPEC BIM | - | ||
ConceptualCost | NATSPEC BIM | - | ||
CostOverRun | NATSPEC BIM | - | ||
FutureCostAssumptions | NATSPEC BIM | - | ||
InstallationCost | NATSPEC BIM | - | ||
InstalledCost | NATSPEC BIM | - | ||
PurchaseInformation | NATSPEC BIM | - | ||
RecordedActualCost | NATSPEC BIM | - | ||
ShippingCost | NATSPEC BIM | - | ||
TotalOwnershipCost | NATSPEC BIM | - | ||
Admin - Identification properties | ||||
GISTag | NATSPEC BIM | - | ||
GPSTag | NATSPEC BIM | - | ||
ArticleNumber | Pset_ManufacturerTypeInformation (IFC2X3) Pset_ManufacturerTypeInformation (IFC4) OBOS Mandatory | Article number or reference that may be applied to a product according to a standard scheme for article number definition (e.g. UN, EAN). | - | |
ModelReference | Pset_ManufacturerTypeInformation (IFC2X3) Pset_ManufacturerTypeInformation (IFC4) NATSPEC Spec OBOS Mandatory | The name of the manufactured item as used by the manufacturer. | - | |
ModelLabel | Pset_ManufacturerTypeInformation (IFC2X3) Pset_ManufacturerTypeInformation (IFC4) NATSPEC Spec OBOS Mandatory | The model number and/or unit designator assigned by the manufacturer of the manufactured item. | - | |
BarCode | Pset_ManufacturerOccurrence (IFC2X3) Pset_ManufacturerOccurrence (IFC4) OBOS Optional | The identity of the bar code given to an occurrence of the product. | - | |
SerialNumber | Pset_ManufacturerOccurrence (IFC2X3) Pset_ManufacturerOccurrence (IFC4) OBOS Optional | The serial number assigned to an occurrence of a product. | - | |
BatchReference | Pset_ManufacturerOccurrence (IFC2X3) Pset_ManufacturerOccurrence (IFC4) OBOS Optional | The identity of the batch reference from which an occurrence of a product is taken. | - | |
GlobalTradeItemNumber | Pset_ManufacturerTypeInformation (IFC4) OBOS Mandatory | The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org). | - | |
Admin - Maintenance properties | ||||
AcquisitionDate | Pset_ManufacturerOccurrence (IFC2X3) Pset_ManufacturerOccurrence (IFC4) OBOS Optional | The date that the manufactured item was purchased. | - | |
ServiceLifeDuration | Pset_ServiceLife (IFC4) OBOS Optional | The length or duration of a service life. The lower bound indicates pessimistic service life, the upper bound indicates optimistic service life, and the setpoint indicates the typical service life. | - | |
MeanTimeBetweenFailure | Pset_ServiceLife (IFC4) OBOS Optional | The average time duration between instances of failure of a product. | - | |
WarrantyIdentifier | Pset_Warranty (IFC4) OBOS Optional | The identifier assigned to a warranty. | - | |
WarrantyStartDate | Pset_Warranty (IFC4) OBOS Optional | The date on which the warranty commences. | - | |
WarrantyEndDate | Pset_Warranty (IFC4) OBOS Optional | The date on which the warranty expires. | - | |
IsExtendedWarranty | Pset_Warranty (IFC4) OBOS Optional | Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE). | - | |
WarrantyPeriod | Pset_Warranty (IFC4) OBOS Optional | The time duration during which a manufacturer or supplier guarantees or warrants the performance of an artefact. | - | |
WarrantyContent | Pset_Warranty (IFC4) OBOS Optional | The content of the warranty. | - | |
Exclusions | Pset_Warranty (IFC4) OBOS Optional | Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void. | - | |
AssessmentDate | Pset_Condition (IFC4) OBOS Optional | Date on which the overall condition is assessed. | - | |
AssessmentCondition | Pset_Condition (IFC4) OBOS Optional | The overall condition of a product based on an assessment of the contributions to the overall condition made by the various criteria considered. The meanings given to the values of assessed condition should be agreed and documented by local agreements. For instance, is overall condition measured on a scale of 1 - 10 or by assigning names such as Good, OK, Poor. | - | |
AssessmentDescription | Pset_Condition (IFC4) OBOS Optional | Qualitative description of the condition. | - | |
Admin - Metadata properties | ||||
CreatedBy | OBOS Mandatory | The name of the person, organisation or library provider that created the object. | - | |
CreatedByURL | OBOS Mandatory | URL hyperlink to the object creator’s website. | - | |
ModifiedIssue | OBOS Mandatory | To record the last date of issue (version or revision) of the object within an object library. Add the date in the following format <yyyymmdd.no> where the ‘no’ suffix is equal to the number of times the object has been issued on that date. For example 20180316.01. | - | |
Admin - Production properties | ||||
Availability | NATSPEC BIM | - | ||
OrderNumber | NATSPEC BIM | - | ||
ManufacturerURL | OBOS Mandatory | URL hyperlink to the manufacturer’s website. | - | |
ProductURL | OBOS Mandatory | URL hyperlink to further product information, such as technical documentation or installation guides. | - | |
Manufacturer | Pset_ManufacturerTypeInformation (IFC2X3) Pset_ManufacturerTypeInformation (IFC4) NATSPEC Spec OBOS Mandatory | The organization that manufactured and/or assembled the item. | - | |
Status | Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure). | - | |
AssemblyPlace | Pset_ManufacturerTypeInformation (IFC4) OBOS Mandatory | Enumeration defining where the assembly is intended to take place, either in a factory or on the building site. | - | |
PointOfContact | Pset_Warranty (IFC4) OBOS Optional | The organization that should be contacted for action under the terms of the warranty. Note that the role of the organization (manufacturer, supplier, installer etc.) is determined by the IfcActorRole attribute of IfcOrganization. | - | |
Compositional - Construction properties | ||||
NumberOfPoles | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional Pset_ElectricalDeviceCommon (IFC2X3) | The number of live lines that is intended to be handled by the device. | - | |
HasProtectiveEarth | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional Pset_ElectricalDeviceCommon (IFC2X3) | Indicates whether the electrical device has a protective earth connection (=TRUE) or not (= FALSE). | - | |
Accessories | NATSPEC BIM | Details of available accessories. | - | |
BaseType | Pset_PumpOccurrence (IFC4) OBOS Optional | Defines general types of pump bases. FRAME: Frame. BASE: Base. NONE: There is no pump base, such as an inline pump. OTHER: Other type of pump base. | - | |
BaseType | Pset_FlowMovingDevicePump (IFC2X3) | Defines general types of pump bases: FRAME: Frame. BASE: Base. NONE: There is no pump base, such as an inline pump. OTHER: Other type of pump base. | - | |
DriveConnectionType | Pset_PumpOccurrence (IFC4) OBOS Optional | The way the pump drive mechanism is connected to the pump. DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of drive connection. | - | |
DriveConnectionType | Pset_FlowMovingDevicePump (IFC2X3) | The way the pump drive mechanism is connected to the pump: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of drive connection. | - | |
DischargeType | Pset_FlowMovingDeviceFan (IFC2X3) | Defines the type of connection at the fan discharge. Duct: Discharge into ductwork. Screen: Discharge into screen outlet. Louver: Discharge into a louver. Damper: Discharge into a damper. | - | |
CoilPosition | Pset_FlowMovingDeviceFan (IFC2X3) | Defines the relationship between a fan and a coil. DrawThrough: Fan located downstream of the coil. BlowThrough: Fan located upstream of the coil. | - | |
MotorPosition | Pset_FlowMovingDeviceFan (IFC2X3) | Defines the location of the motor relative to the air stream. InAirStream: Fan motor is in the air stream. OutOfAirStream: Fan motor is out of the air stream. | - | |
FanMountingType | Pset_FlowMovingDeviceFan (IFC2X3) | Defines the method of mounting the fan in the building. | - | |
NumberOfBoltholes | Pset_PipeConnectionFlanged (IFC2X3) | Number of boltholes in the flange. | - | |
ConnectionType | Pset_PipeConnection (IFC2X3) | The connection type between pipe segments or fittings and other segments or fittings. If the list contains only one value, then this connection type value applies to all ports. For more than one value in the list, the connection type value applies to the port that corresponds to the list index.The following suggested items should be utilized whenever possible for correlation with port enumerations: BRAZED: Brazed connection type. COMPRESSION: Compression connection type. FLANGED: Flanged connection type including bolts and gasket. GLANDJOINT: Gland-joint connection type. FLEXIBLEBOLTEDGLANDJOINT: Flexible bolted gland-joint connection type. FLEXIBLEBOLTEDGLANDJOINTWITHANODEENDCAP: Flexible bolted gland-joint with anode end-cap connection type. GROOVED: Grooved connection type. SOLDERED: Soldered connection type. SOLDERED_FEMALE: Female-soldered connection type. SOLDERED_MALE: Male-soldered connection type. SWEDGE: Swedge connection type. THREADED: Threaded connection type. THREADED_FEMALE: Female-threaded connection type. THREADED_MALE: Male-threaded connection type. WELDED: Welded connection type. WELDED_BUTT: Butt-welded connection type. WELDED_BRANCH: Branch-welded connection type. WELDED_FLANGE: Flange-welded connection type. NONE: There is no connection. NOTDEFINED: Undefined connection type. | - | |
Compositional - Mass properties | ||||
GrossWeight | Qto_PumpBaseQuantities (IFC4) | Weight of the element. | - | |
Compositional - Material properties | ||||
RecycledContent | NATSPEC BIM | - | ||
CasingMaterial | Pset_PumpTypeCommon (IFC2X3) | Material from which the casing of the pump is constructed | - | |
ImpellerMaterial | Pset_PumpTypeCommon (IFC2X3) | Material from which the impeller of the pump is constructed. In the case of a positive displacement pump, the piston acts as the impeller | - | |
ImpellerSealMaterial | Pset_PumpTypeCommon (IFC2X3) | Material from which the impeller shaft seal of the pump is constructed. | - | |
Material | Pset_PipeConnectionFlanged (IFC2X3) | Material from which the pipe flange is constructed. | - | |
Compositional - Quality properties | ||||
IP_Code | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional Pset_ElectricalDeviceCommon (IFC2X3) | IP Code, the International Protection Marking, IEC 60529), classifies and rates the degree of protection provided against intrusion. | - | |
IK_Code | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional | IK Code according to IEC 62262 (2002) is a numeric classification for the degree of protection provided by enclosures for electrical equipment against external mechanical impacts. > NOTE In earlier labeling, the third numeral (1..) had been occasionally added to the closely related IP Code on ingress protection, to indicate the level of impact protection. | - | |
Defects | NATSPEC BIM | To record any defects found. | - | |
Geometric - Dimensional properties | ||||
ConnectionSize | Pset_PumpTypeCommon (IFC2X3) Pset_PumpTypeCommon (IFC4) OBOS Mandatory | The connection size of the to and from the pump | m | |
ImpellerDiameter | Pset_PumpOccurrence (IFC4) OBOS Optional | Diameter of pump impeller - used to scale performance of geometrically similar pumps. | m | |
ImpellerDiameter | Pset_FlowMovingDevicePump (IFC2X3) | Diameter of pump impeller - used to scale performance of geometrically similar pumps. | m | |
ImpellerDiameter | Pset_FlowMovingDeviceCompressor (IFC2X3) | Diameter of compressor impeller - used to scale performance of geometrically similar compressors. | m | |
ImpellerDiameter | Pset_FlowMovingDeviceFan (IFC2X3) | Diameter of fan wheel - used to scale performance of geometrically similar fans. | m | |
BoreSize | Pset_PipeConnectionFlanged (IFC2X3) | The nominal bore of the pipe flange. | m | |
FlangeDiameter | Pset_PipeConnectionFlanged (IFC2X3) | Overall diameter of the flange. | m | |
FlangeThickness | Pset_PipeConnectionFlanged (IFC2X3) | Thickness of the material from which the pipe bend is constructed. | m | |
BoltSize | Pset_PipeConnectionFlanged (IFC2X3) | Size of the bolts securing the flange. | m | |
BoltholePitch | Pset_PipeConnectionFlanged (IFC2X3) | Diameter of the circle along which the boltholes are placed. | m | |
Performance - Acoustic properties | ||||
SoundCurve | Pset_SoundGeneration (IFC4) OBOS Optional | Table of sound frequencies and sound power measured in decibels at a reference power of 1 picowatt(10^(-12) watt) for the referenced octave band frequency. | Hz | |
Performance - Electrical properties | ||||
RatedCurrent | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional | The current that a device is designed to handle. | A | |
RatedVoltage | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional | The voltage that a device is designed to handle. | V | |
NominalFrequencyRange | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional Pset_ElectricalDeviceCommon (IFC2X3) | The upper and lower limits of frequency for which the operation of the device is certified. | Hz | |
PowerFactor | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional | The ratio between the rated electrical power and the product of the rated current and rated voltage. | - | |
ConductorFunction | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional | Function of a line conductor to which a device is intended to be connected where L1, L2 and L3 represent the phase lines according to IEC 60446 notation (sometimes phase lines may be referenced by color [Red, Blue, Yellow] or by number [1, 2, 3] etc). Protective Earth is sometimes also known as CPC or common protective conductor. Note that for an electrical device, a set of line conductor functions may be applied. | - | |
InsulationStandardClass | Pset_ElectricalDeviceCommon (IFC4) OBOS Optional Pset_ElectricalDeviceCommon (IFC2X3) | Insulation standard classes provides basic protection information against electric shock. Defines levels of insulation required in terms of constructional requirements (creepage and clearance distances) and electrical requirements (compliance with electric strength tests). Basic insulation is considered to be shorted under single fault conditions. The actual values required depend on the working voltage to which the insulation is subjected, as well as other factors. Also indicates whether the electrical device has a protective earth connection. | - | |
NominalCurrent | Pset_ElectricalDeviceCommon (IFC2X3) | The maximum allowed current that a device is certified to handle. | A | |
UsageCurrent | Pset_ElectricalDeviceCommon (IFC2X3) | The current that a device is actually handling or is calculated to be handling at a point in time. | A | |
NominalVoltage | Pset_ElectricalDeviceCommon (IFC2X3) | The range of allowed voltage that a device is certified to handle. The upper bound of this value is the maximum. | V | |
ElectricalDeviceNominalPower | Pset_ElectricalDeviceCommon (IFC2X3) | The output power rating that is certified for a device. | W | |
PhaseAngle | Pset_ElectricalDeviceCommon (IFC2X3) | The angular difference between two waveforms of the same frequency. | rad | |
PhaseReference | Pset_ElectricalDeviceCommon (IFC2X3) | The phase identification used for the device electrical input. This should be the same phase identifier that is used for the conductor segment providing the electrical service to the device. In general, it is recommended that IEC recommendations for phase identification are used (L1, L2 etc.). However, other phase identifiers may be used such as by color (Red, Blue, Yellow) or by number (1, 2, 3) etc. | - | |
Performance - Environmental properties | ||||
CarbonFootprint | NATSPEC BIM | - | ||
ItemIsNew | NATSPEC BIM | - | ||
ItemIsPartiallyRecycled | NATSPEC BIM | - | ||
ItemIsRecycled | NATSPEC BIM | - | ||
PostConsumerRecycledContent | NATSPEC BIM | - | ||
PostIndustrialRecycledContent | NATSPEC BIM | - | ||
PreConsumerRecycledContent | NATSPEC BIM | - | ||
FunctionalUnitReference | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Reference to a database or a classification. | - | |
Unit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | The unit of the quantity the environmental indicators values are related with. | - | |
LifeCyclePhase | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | The whole life cycle or only a given phase from which environmental data are valid. | - | |
ExpectedServiceLife | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Expected service life in years. | s | |
TotalPrimaryEnergyConsumptionPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of energy used as defined in ISO21930:2007. | J | |
WaterConsumptionPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of water used. | m³ | |
HazardousWastePerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of hazardous waste generated. | kg | |
NonHazardousWastePerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of non hazardous waste generated. | kg | |
ClimateChangePerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of greenhouse gases emitted calculated in equivalent CO2. | kg | |
AtmosphericAcidificationPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2. | kg | |
RenewableEnergyConsumptionPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of renewable energy used as defined in ISO21930:2007. | J | |
NonRenewableEnergyConsumptionPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of non-renewable energy used as defined in ISO21930:2007. | J | |
ResourceDepletionPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of resources used calculated in equivalent antimony. | kg | |
InertWastePerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of inert waste generated. | kg | |
RadioactiveWastePerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of radioactive waste generated. | kg | |
StratosphericOzoneLayerDestructionPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11. | kg | |
PhotochemicalOzoneFormationPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of gases creating the photochemical ozone calculated in equivalent ethylene. | kg | |
EutrophicationPerUnit | Pset_EnvironmentalImpactIndicators (IFC4) OBOS Optional | Quantity of eutrophicating compounds calculated in equivalent PO4. | kg | |
TotalPrimaryEnergyConsumption | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of energy used as defined in ISO21930:2007. | J | |
WaterConsumption | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of water used. | m³ | |
HazardousWaste | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of hazardous waste generated. | kg | |
NonHazardousWaste | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of non hazardous waste generated. | kg | |
ClimateChange | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of greenhouse gases emitted calculated in equivalent CO2. | kg | |
AtmosphericAcidification | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2. | kg | |
RenewableEnergyConsumption | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of renewable energy used as defined in ISO21930:2007. | J | |
NonRenewableEnergyConsumption | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of non-renewable energy used as defined in ISO21930:2007. | J | |
ResourceDepletion | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of resources used calculated in equivalent antimony. | kg | |
InertWaste | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of inert waste generated. | kg | |
RadioactiveWaste | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of radioactive waste generated. | kg | |
StratosphericOzoneLayerDestruction | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11. | kg | |
PhotochemicalOzoneFormation | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of gases creating the photochemical ozone calculated in equivalent ethylene. | kg | |
Eutrophication | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Quantity of eutrophicating compounds calculated in equivalent PO4. | kg | |
Performance - Fire properties | ||||
FireResistanceRating | Pset_FireRatingProperties (IFC2X3) | Fire rating identifying the entity's fire resistive value (e.g., 1-hour, 2-hour, etc.) so that its resistance to fire can be compared to that of the surrounding structure. | - | |
IsCombustible | Pset_FireRatingProperties (IFC2X3) | Combustibility (YES it is combustible or NO it is not combustible). | - | |
SurfaceSpreadOfFlame | Pset_FireRatingProperties (IFC2X3) | Surface spread of flame characteristics. | - | |
Performance - Mechanical characteristics properties | ||||
NominalRotationSpeed | Pset_PumpTypeCommon (IFC2X3) Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Pump rotational speed under nominal conditions. | cycles/s | |
Performance - Thermal properties | ||||
TemperatureRange | Pset_PumpTypeCommon (IFC2X3) Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Allowable operational range of the fluid temperature. | °C | |
FractionOfMotorHeatToAirStream | Pset_FlowMovingDeviceFan (IFC2X3) | Fraction of the motor heat released into the fluid flow. | - | |
Performance - Usage properties | ||||
FlowRateRange | Pset_PumpTypeCommon (IFC2X3) Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Allowable range of volume of fluid being pumped against the resistance specified. | kg/s | |
FlowResistanceRange | Pset_PumpTypeCommon (IFC2X3) Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Allowable range of frictional resistance against which the fluid is being pumped | Pa | |
NetPositiveSuctionHead | Pset_PumpTypeCommon (IFC2X3) Pset_PumpTypeCommon (IFC4) OBOS Mandatory | Minimum liquid pressure at the pump inlet to prevent cavitation. | Pa | |
MechanicalEfficiency | Pset_PumpPHistory (IFC4) OBOS Optional | The pumps operational mechanical efficiency. | - | |
OverallEfficiency | Pset_PumpPHistory (IFC4) OBOS Optional | The pump and motor overall operational efficiency. | - | |
PressureRise | Pset_PumpPHistory (IFC4) OBOS Optional | The developed pressure. | - | |
RotationSpeed | Pset_PumpPHistory (IFC4) OBOS Optional | Pump rotational speed. | - | |
Flowrate | Pset_PumpPHistory (IFC4) OBOS Optional | The actual operational fluid flowrate. | - | |
Power | Pset_PumpPHistory (IFC4) OBOS Optional | The actual power consumption of the pump. | - | |
ApplicationOfFan | Pset_FlowMovingDeviceFan (IFC2X3) | The functional application of the fan: SUPPLYAIR: Supply air fan. RETURNAIR: Return air fan. EXHAUSTAIR: Exhaust air fan. OTHER: Other type of application not defined above. | - | |
Time - Object time properties | ||||
DeliverBy | NATSPEC BIM | - | ||
FabricationTime | NATSPEC BIM | - | ||
InstallationSequence | NATSPEC BIM | - | ||
InstallationTime | NATSPEC BIM | - | ||
LeadTime | NATSPEC BIM | - | ||
ProductionYear | Pset_ManufacturerTypeInformation (IFC2X3) Pset_ManufacturerTypeInformation (IFC4) OBOS Mandatory | The year of production of the manufactured item. | - | |
Time - Project time properties | ||||
LeadInTime | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Lead in time before start of process. | - | |
Duration | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Duration of process. | - | |
LeadOutTime | Pset_EnvironmentalImpactValues (IFC4) OBOS Optional | Lead out time after end of process. | - |