Properties Generator v2.0

Ground fault interrupter (Residual current circuit breaker)

A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded. A protective device may include both the tripping unit and the breaking unit or it may simply represent the breaking unit if the tripping unit is specified individually as a protective device tripping unit.

A ground fault interrupter (residual current circuit breaker) is a protective device that opens, closes, or isolates a circuit and has short circuit and overload protection. It attempts to break the circuit when there is a difference in current between any two phases. May also be referred to as a 'Ground Fault Circuit Interruptor (GFCI)'

IfcElementType IfcProtectiveDevice =IfcExportAs
IfcPredefinedType RESIDUALCURRENTCIRCUITBREAKER =IfcExportType
Suggested Filename Power_GFI
Suggested LOD (Design Model) 200
Suggested Primary Discipline Electrical
Specific classifications
(Select the classification you'd like to be included in the Excel export)
AusHFG
ICMS
NATSPEC
OmniClass 21 Elements
OmniClass 22 Work Results
OmniClass 23 Products
Uniclass EF Elements Functions
Uniclass Pr Products
Uniclass Ss Systems
UniFormat
PropertySourceDescriptionValueUnit
Admin - Classification properties
Reference
Pset_DistributionFlowElementCommon (IFC2X3)

Reference ID for this specific instance (e.g. 'WWS/VS1/400/001', which indicates the occurrence belongs to system WWS, subsystems VSI/400, and has the component number 001).

-
Reference
Pset_ProtectiveDeviceTypeCommon (IFC4)
OBOS Mandatory

Reference ID for this specified type in this project (e.g. type 'A-1'), provided, if there is no classification reference to a recognized classification system used.

-
SpecificationCode
OBOS Optional

Specification clause or section code/reference.

-
SpecificationSystem
OBOS Optional

Name of the specification system being used.

-
SpecificationTitle
OBOS Optional

Specification clause or section title.

-
SpecificationVersion
OBOS Optional

Published version of the classification system.

-
Admin - Cost properties
AdditionalTax
NATSPEC BIM
-
AssemblyCost
NATSPEC BIM
-
ConceptualCost
NATSPEC BIM
-
CostOverRun
NATSPEC BIM
-
FutureCostAssumptions
NATSPEC BIM
-
InstallationCost
NATSPEC BIM
-
InstalledCost
NATSPEC BIM
-
PurchaseInformation
NATSPEC BIM
-
RecordedActualCost
NATSPEC BIM
-
ShippingCost
NATSPEC BIM
-
TotalOwnershipCost
NATSPEC BIM
-
Admin - Identification properties
GISTag
NATSPEC BIM
-
GPSTag
NATSPEC BIM
-
ArticleNumber
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

Article number or reference that may be applied to a product according to a standard scheme for article number definition (e.g. UN, EAN).

-
ModelReference
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
NATSPEC Spec
OBOS Mandatory

The name of the manufactured item as used by the manufacturer.

-
ModelLabel
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
NATSPEC Spec
OBOS Mandatory

The model number and/or unit designator assigned by the manufacturer of the manufactured item.

-
BarCode
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The identity of the bar code given to an occurrence of the product.

-
SerialNumber
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The serial number assigned to an occurrence of a product.

-
BatchReference
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The identity of the batch reference from which an occurrence of a product is taken.

-
GlobalTradeItemNumber
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org).

-
Admin - Maintenance properties
AcquisitionDate
Pset_ManufacturerOccurrence (IFC2X3)
Pset_ManufacturerOccurrence (IFC4)
OBOS Optional

The date that the manufactured item was purchased.

-
ServiceLifeDuration
Pset_ServiceLife (IFC4)
OBOS Optional

The length or duration of a service life. The lower bound indicates pessimistic service life, the upper bound indicates optimistic service life, and the setpoint indicates the typical service life.

-
MeanTimeBetweenFailure
Pset_ServiceLife (IFC4)
OBOS Optional

The average time duration between instances of failure of a product.

-
WarrantyIdentifier
Pset_Warranty (IFC4)
OBOS Optional

The identifier assigned to a warranty.

-
WarrantyStartDate
Pset_Warranty (IFC4)
OBOS Optional

The date on which the warranty commences.

-
WarrantyEndDate
Pset_Warranty (IFC4)
OBOS Optional

The date on which the warranty expires.

-
IsExtendedWarranty
Pset_Warranty (IFC4)
OBOS Optional

Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE).

-
WarrantyPeriod
Pset_Warranty (IFC4)
OBOS Optional

The time duration during which a manufacturer or supplier guarantees or warrants the performance of an artefact.

-
WarrantyContent
Pset_Warranty (IFC4)
OBOS Optional

The content of the warranty.

-
Exclusions
Pset_Warranty (IFC4)
OBOS Optional

Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void.

-
AssessmentDate
Pset_Condition (IFC4)
OBOS Optional

Date on which the overall condition is assessed.

-
AssessmentCondition
Pset_Condition (IFC4)
OBOS Optional

The overall condition of a product based on an assessment of the contributions to the overall condition made by the various criteria considered. The meanings given to the values of assessed condition should be agreed and documented by local agreements. For instance, is overall condition measured on a scale of 1 - 10 or by assigning names such as Good, OK, Poor.

-
AssessmentDescription
Pset_Condition (IFC4)
OBOS Optional

Qualitative description of the condition.

-
Admin - Metadata properties
CreatedBy
OBOS Mandatory

The name of the person, organisation or library provider that created the object.

-
CreatedByURL
OBOS Mandatory

URL hyperlink to the object creator’s website.

-
ModifiedIssue
OBOS Mandatory

To record the last date of issue (version or revision) of the object within an object library. Add the date in the following format <yyyymmdd.no> where the ‘no’ suffix is equal to the number of times the object has been issued on that date. For example 20180316.01.

-
Admin - Production properties
Availability
NATSPEC BIM
-
OrderNumber
NATSPEC BIM
-
ManufacturerURL
OBOS Mandatory

URL hyperlink to the manufacturer’s website.

-
ProductURL
OBOS Mandatory

URL hyperlink to further product information, such as technical documentation or installation guides.

-
Manufacturer
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
NATSPEC Spec
OBOS Mandatory

The organization that manufactured and/or assembled the item.

-
AssemblyPlace
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

Enumeration defining where the assembly is intended to take place, either in a factory or on the building site.

-
PointOfContact
Pset_Warranty (IFC4)
OBOS Optional

The organization that should be contacted for action under the terms of the warranty. Note that the role of the organization (manufacturer, supplier, installer etc.) is determined by the IfcActorRole attribute of IfcOrganization.

-
Status
Pset_ProtectiveDeviceTypeCommon (IFC4)
OBOS Mandatory

Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).

-
Compositional - Construction properties
NumberOfPoles
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

The number of live lines that is intended to be handled by the device.

-
HasProtectiveEarth
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

Indicates whether the electrical device has a protective earth connection (=TRUE) or not (= FALSE).

-
Accessories
NATSPEC BIM

Details of available accessories.

-
Compositional - Mass properties
GrossWeight
Qto_ProtectiveDeviceBaseQuantities (IFC4)

Weight of the element.

-
Compositional - Material properties
RecycledContent
NATSPEC BIM
-
Compositional - Quality properties
IP_Code
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

IP Code, the International Protection Marking, IEC 60529), classifies and rates the degree of protection provided against intrusion.

-
IK_Code
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

IK Code according to IEC 62262 (2002) is a numeric classification for the degree of protection provided by enclosures for electrical equipment against external mechanical impacts. > NOTE  In earlier labeling, the third numeral (1..) had been occasionally added to the closely related IP Code on ingress protection, to indicate the level of impact protection.

-
Defects
NATSPEC BIM

To record any defects found.

-
Geometric - Dimensional properties
SizingMethod
Pset_FlowControllerDamper (IFC2X3)

Identifies whether the damper is sized nominally or with exact measurements: NOMINAL: Nominal sizing method. EXACT: Exact sizing method.

-
Performance - Acoustic properties
SoundCurve
Pset_SoundGeneration (IFC4)
OBOS Optional

Table of sound frequencies and sound power measured in decibels at a reference power of 1 picowatt(10^(-12) watt) for the referenced octave band frequency.

Hz
Performance - Electrical properties
RatedCurrent
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

The current that a device is designed to handle.

A
RatedVoltage
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

The voltage that a device is designed to handle.

V
NominalFrequencyRange
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

The upper and lower limits of frequency for which the operation of the device is certified.

Hz
PowerFactor
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

The ratio between the rated electrical power and the product of the rated current and rated voltage.

-
ConductorFunction
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional

Function of a line conductor to which a device is intended to be connected where L1, L2 and L3 represent the phase lines according to IEC 60446 notation (sometimes phase lines may be referenced by color [Red, Blue, Yellow] or by number [1, 2, 3] etc). Protective Earth is sometimes also known as CPC or common protective conductor. Note that for an electrical device, a set of line conductor functions may be applied.

-
InsulationStandardClass
Pset_ElectricalDeviceCommon (IFC4)
OBOS Optional
Pset_ElectricalDeviceCommon (IFC2X3)

Insulation standard classes provides basic protection information against electric shock. Defines levels of insulation required in terms of constructional requirements (creepage and clearance distances) and electrical requirements (compliance with electric strength tests). Basic insulation is considered to be shorted under single fault conditions. The actual values required depend on the working voltage to which the insulation is subjected, as well as other factors. Also indicates whether the electrical device has a protective earth connection.

-
Sensitivity
Pset_ProtectiveDeviceTypeResidualCurrentCircuitBreaker (IFC2X3)
Pset_ProtectiveDeviceTypeResidualCurrentCircuitBreaker (IFC4)
OBOS Mandatory

Current leakage to an unwanted leading path during normal operation (IEC 151-14-49)

A
RatedShortCircuitCurrent
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

An overcurrent resulting from a fault of negligible impedance between live conductors having a difference in potential under normal operating conditions. (IEC 826-05-08)

A
CutOffCurrent
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

The maximum instantaneous value of current attained during the breaking operation of a protective device. (IEC 441-17-12)

A
MaximumRatedVoltage
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

Maximum rated voltage

V
LimitingTerminalSize
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

The maximum terminal size capacity of the device.

SwitchingDuty
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

The maximum number of operations for the device at the rated making and breaking capacity.

-
CharacteristicTripCurve
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

A curve giving the time, e.g. prearcing time or operating time, as a function of the protective current under stated conditions of operation.

A
ProtectiveTagType
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

The breaking capacity value of the device. Note: This may be expressed as a code or a value depending on standard and/or source.

-
StandardUsed
Pset_ProtectiveDeviceTypeCommon (IFC2X3)

The electrical standard used as a reference when preparing data for the device.

-
PoleUsage
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Pole usage.

-
LongTimeFunction
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Applying long time function A flag indicating that the long time function (i.e. the thermal tripping) of the device is used. The value should be set to TRUE for all devices except those that allows the Long time function of the device not to be used.

-
ShortTimeFunction
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Applying short time function A flag indicating that the short time function of the device is used. The value should be set to FALSE for devices not having a short time function, or if the short time function is not selected to be used.

-
ShortTimei2tFunction
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Applying short time i2t function. A flag indicating that the I2t short time function of the device is used. The value should be set to TRUE only if the I2t function  is explicitly selected for the device.

-
GroundFaultFunction
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Applying ground fault function. A flag indicating that the ground fault function of the device is used. The value should be set to FALSE for devices not having a ground fault function, or if the ground fault function is not selected to be used.

-
GroundFaulti2tFunction
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Applying ground fault i2t function. A flag indicating that the I2t ground fault function of the device is used. The value should be set to TRUE only if the I2t function is explicitly selected for the device.

-
LongTimeCurrentSetValue
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Long time current set value. The set value of the long time tripping current if adjustable.

A
ShortTimeCurrentSetValue
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Short time current set value. The set value of the long time tripping current if adjustable.

A
InstantaneousCurrentSetValue
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Instantaneous current set value. The set value of the instantaneous tripping current if adjustable.

A
GroundFaultCurrentSetValue
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Ground fault current set value. The set value of the ground tripping current if adjustable.

A
LongTimeDelay
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Long time delay. The set value of the long time time-delay if adjustable.

s
ShortTimeTrippingTime
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Short time tripping time. The set value of the short time tripping time if adjustable.

s
InstantaneousTrippingTime
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Instantaneous tripping time. The set value of the instantaneous tripping time if adjustable.

s
GroundFaultTrippingTime
Pset_ProtectiveDeviceOccurrence (IFC4)
OBOS Optional

Ground fault tripping time. The set value of the ground fault tripping current if adjustable.

s
PerformanceClasses
Pset_ProtectiveDeviceBreakerUnitTypeMotorProtection (IFC4)
OBOS Mandatory

A set of designations of performance classes for the breaker unit for which the data of this instance is valid. A breaker unit being a motor protection device may be constructed for different levels of breaking capacities. A maximum of 7 different performance classes may be provided. Examples of performance classes that may be specified include B, C, N, S, H, L, V.

-
ICU60947
Pset_ProtectiveDeviceBreakerUnitTypeMotorProtection (IFC4)
OBOS Mandatory

The ultimate breaking capacity in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series.

A
ICS60947
Pset_ProtectiveDeviceBreakerUnitTypeMotorProtection (IFC4)
OBOS Mandatory

The service breaking capacity in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series.

A
ICW60947
Pset_ProtectiveDeviceBreakerUnitTypeMotorProtection (IFC4)
OBOS Mandatory

The thermal withstand current in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series. The value shall be related to 1 s.

A
ICM60947
Pset_ProtectiveDeviceBreakerUnitTypeMotorProtection (IFC4)
OBOS Mandatory

The making capacity in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series.

A
BreakerUnitCurve
Pset_ProtectiveDeviceBreakerUnitI2TCurve (IFC4)
OBOS Optional

A curve that establishes the let through energy of a breaker unit when a particular prospective current is applied. Note that the breaker unit curve is defined within a Cartesian coordinate system and this fact must be asserted within the property set: (1) Defining value: ProspectiveCurrent: A list of minimum 2 and maximum 16 numbers providing the currents in [A] for points in the current/I2t log/log coordinate space. The curve is drawn as a straight line between two consecutive points. (2) Defined value: LetThroughEnergy: A list of minimum 2 and maximum 16 numbers providing the let-through energy, I2t, in [A2s] for points in the current/I2t log/log coordinate space. The curve is drawn as a straight line between two consecutive points.

A
BreakerUnitFuseMeltingCurve
Pset_ProtectiveDeviceBreakerUnitI2TFuseCurve (IFC4)
OBOS Optional

A curve that establishes the energy required to melt the fuse of a breaker unit when a particular prospective melting current is applied. Note that the breaker unit fuse melting curve is defined within a Cartesian coordinate system and this fact must be: (1) Defining value: ProspectiveCurrentMelting :A list of minimum 2 and maximum 8 numbers providing the currents in [A] for points in the current/melting_energy log/log coordinate space. The curve is drawn as a straight line between two consecutive points. (2) Defined value: MeltingEnergy: A list of minimum 2 and maximum 8 numbers providing the energy whereby the fuse is starting to melt, I2t, in [A2s] for points in the current/melting_energy log/log coordinate space. The curve is drawn as a straight line between two consecutive points.

A
BreakerUnitFuseBreakingingCurve
Pset_ProtectiveDeviceBreakerUnitI2TFuseCurve (IFC4)
OBOS Optional

A curve that establishes the let through breaking energy of a breaker unit when a particular prospective breaking current is applied. Note that the breaker unit fuse breaking curve is defined within a Cartesian coordinate system and this fact must be: (1) Defining value: ProspectiveCurrentBreaking: A list of minimum 2 and maximum 8 numbers providing the currents in [A] for points in the current/breaking energy log/log coordinate space. The curve is drawn as a straight line between two consecutive points. (2) Defined value: LetThroughBreakingEnergy: A list of minimum 2 and maximum 8 numbers providing the breaking energy whereby the fuse has provided a break, I2t, in [A2s] for points in the current/breakting_energy log/log coordinate space. The curve is drawn as a straight line between two consecutive.

A
VoltageLevel
Pset_ProtectiveDeviceBreakerUnitIPICurve (IFC4)
OBOS Optional

The voltage level of the protective device for which the data of the instance is valid. More than one value may be selected in the enumeration.

-
NominalCurrent
Pset_ProtectiveDeviceBreakerUnitIPICurve (IFC4)
OBOS Optional

A set of nominal currents in [A] for which the data of this instance is valid. At least one value shall be provided. Any value in the set shall not exceed the value of the UltimateRatedCurrent associated with the same breaker unit.

A
NominalCurrent
Pset_ElectricalDeviceCommon (IFC2X3)

The maximum allowed current that a device is certified to handle.

A
BreakerUnitIPICurve
Pset_ProtectiveDeviceBreakerUnitIPICurve (IFC4)
OBOS Optional

A curve that establishes the let through peak current of a breaker unit when a particular prospective current is applied. Note that the breaker unit IPI curve is defined within a Cartesian coordinate system and this fact must be asserted within the property set: (1) Defining value: A list of minimum 2 and maximum 16 numbers providing the currents in [A] for points in the I/Î log/log coordinate space. The curve is drawn as a straight line between two consecutive points. (2) Defined value: A list of minimum 2 and maximum 16 numbers providing the let-through peak currents, Î, in [A] for points in the I/Î log/log coordinate space. The curve is drawn as a straight line between two consecutive points.

A
TrippingCurveType
Pset_ProtectiveDeviceTrippingCurve (IFC4)
OBOS Optional

The type of tripping curve that is represented by the property set.

-
TrippingCurve
Pset_ProtectiveDeviceTrippingCurve (IFC4)
OBOS Optional

A curve that establishes the release time of a tripping unit when a particular prospective current is applied. Note that the tripping curve is defined within a Cartesian coordinate system and this fact must be asserted within the property set: (1) Defining value is the Prospective Current which is a list of minimum 2 and maximum 16 numbers providing the currents in [x In] for points in the current/time log/log coordinate space. The curve is drawn as a straight line between two consecutive points. (2) Defined value is a list of minimum 2 and maximum 16 numbers providing the release_time in [s] for points in the current/time log/log coordinate space. The curve is drawn as a straight line between two consecutive points. Note that a defined interpolation.

A
UsageCurrent
Pset_ElectricalDeviceCommon (IFC2X3)

The current that a device is actually handling or is calculated to be handling at a point in time.

A
NominalVoltage
Pset_ElectricalDeviceCommon (IFC2X3)

The range of allowed voltage that a device is certified to handle. The upper bound of this value is the maximum.

V
ElectricalDeviceNominalPower
Pset_ElectricalDeviceCommon (IFC2X3)

The output power rating that is certified for a device.

W
PhaseAngle
Pset_ElectricalDeviceCommon (IFC2X3)

The angular difference between two waveforms of the same frequency.

rad
PhaseReference
Pset_ElectricalDeviceCommon (IFC2X3)

The phase identification used for the device electrical input. This should be the same phase identifier that is used for the conductor segment providing the electrical service to the device. In general, it is recommended that IEC recommendations for phase identification are used (L1, L2 etc.). However, other phase identifiers may be used such as by color (Red, Blue, Yellow) or by number (1, 2, 3) etc.

-
Performance - Environmental properties
CarbonFootprint
NATSPEC BIM
-
ItemIsNew
NATSPEC BIM
-
ItemIsPartiallyRecycled
NATSPEC BIM
-
ItemIsRecycled
NATSPEC BIM
-
PostConsumerRecycledContent
NATSPEC BIM
-
PostIndustrialRecycledContent
NATSPEC BIM
-
PreConsumerRecycledContent
NATSPEC BIM
-
FunctionalUnitReference
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Reference to a database or a classification.

-
Unit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

The unit of the quantity the environmental indicators values are related with.

-
LifeCyclePhase
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

The whole life cycle or only a given phase from which environmental data are valid.

-
ExpectedServiceLife
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Expected service life in years.

s
TotalPrimaryEnergyConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of energy used as defined in ISO21930:2007.

J
WaterConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of water used.

HazardousWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of hazardous waste generated.

kg
NonHazardousWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of non hazardous waste generated.

kg
ClimateChangePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of greenhouse gases emitted calculated in equivalent CO2.

kg
AtmosphericAcidificationPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2.

kg
RenewableEnergyConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of renewable energy used as defined in ISO21930:2007.

J
NonRenewableEnergyConsumptionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of non-renewable energy used as defined in ISO21930:2007.

J
ResourceDepletionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of resources used calculated in equivalent antimony.

kg
InertWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of inert waste generated.

kg
RadioactiveWastePerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of radioactive waste generated.

kg
StratosphericOzoneLayerDestructionPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11.

kg
PhotochemicalOzoneFormationPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of gases creating the photochemical ozone calculated in equivalent ethylene.

kg
EutrophicationPerUnit
Pset_EnvironmentalImpactIndicators (IFC4)
OBOS Optional

Quantity of eutrophicating compounds calculated in equivalent PO4.

kg
TotalPrimaryEnergyConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of energy used as defined in ISO21930:2007.

J
WaterConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of water used.

HazardousWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of hazardous waste generated.

kg
NonHazardousWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of non hazardous waste generated.

kg
ClimateChange
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of greenhouse gases emitted calculated in equivalent CO2.

kg
AtmosphericAcidification
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2.

kg
RenewableEnergyConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of renewable energy used as defined in ISO21930:2007.

J
NonRenewableEnergyConsumption
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of non-renewable energy used as defined in ISO21930:2007.

J
ResourceDepletion
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of resources used calculated in equivalent antimony.

kg
InertWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of inert waste generated.

kg
RadioactiveWaste
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of radioactive waste generated.

kg
StratosphericOzoneLayerDestruction
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11.

kg
PhotochemicalOzoneFormation
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of gases creating the photochemical ozone calculated in equivalent ethylene.

kg
Eutrophication
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Quantity of eutrophicating compounds calculated in equivalent PO4.

kg
Performance - Fire properties
FireResistanceRating
Pset_FireRatingProperties (IFC2X3)

Fire rating identifying the entity's fire resistive value (e.g., 1-hour, 2-hour, etc.) so that its resistance to fire can be compared to that of the surrounding structure.

-
IsCombustible
Pset_FireRatingProperties (IFC2X3)

Combustibility (YES it is combustible or NO it is not combustible).

-
SurfaceSpreadOfFlame
Pset_FireRatingProperties (IFC2X3)

Surface spread of flame characteristics.

-
Performance - Usage properties
Purpose
Pset_FlowControllerFlowMeter (IFC2X3)

Enumeration defining the purpose of the flow meter occurrence.

-
Time - Object time properties
DeliverBy
NATSPEC BIM
-
FabricationTime
NATSPEC BIM
-
InstallationSequence
NATSPEC BIM
-
InstallationTime
NATSPEC BIM
-
LeadTime
NATSPEC BIM
-
ProductionYear
Pset_ManufacturerTypeInformation (IFC2X3)
Pset_ManufacturerTypeInformation (IFC4)
OBOS Mandatory

The year of production of the manufactured item.

-
Time - Project time properties
LeadInTime
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Lead in time before start of process.

-
Duration
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Duration of process.

-
LeadOutTime
Pset_EnvironmentalImpactValues (IFC4)
OBOS Optional

Lead out time after end of process.

-
Application version 2.0.3.1   Data version 2.0.3
© 2025 Level 4, 263 Clarence Street
SYDNEY NSW 2000
Australia